Exam Number/Code: e20-822
Questions and Answers:120 Q&As
Updated Time: 2009-09-25
Register for Exam: Prometric/Pearson VUE
Exam Name:CLARiiON Solutions Expert Exam for Storage Administrators
The following are the e20-822 exam answers we get from all of the world company exams vendors include : examsoon e20-822 exam ,Testinside e20-822 braindumps, Pass4sure e20-822 practice exam , Testking e20-822 study guides, exam4sure trainning materials. after you read the following e20-822 exam demo questions and answers, you will see the high quanity of the exam
The e20-822 exam products are designed to maximize your learning productivity and focus only on the important aspects that will help you to pass your e20-822 test. We will provide you with e20-822 exam questions and verified answers, that reflect the actual exam. These questions and answers provide you with the experience of taking the e20-822 actual test. e20-822 exam guides are not just questions and answers. e20-822 questions have detailed for every answer, ensuring that you fully understand the questions and the concept behind the questions.
Free 640-802 Demo Download
Free demo for EMC EMC Certification e20-822 exam (CLARiiON Solutions Expert Exam for Storage Administrators). You can check out the interface, question quality and usability of our practice exams
Free Download 640-802 Exam Pdf Demo
Free Download 640-802 Exam iEngine Demo
Exam : EMC E20-822
Title : CLARiiON Solutions Expert
Exam for Storage
Administrators
1. Click the Exhibit button.
The application using LUN 21 performs mainly 16 kB I/O operations. What is true of LUN 21?
A. Read performance would improve if read cache was increased from 250 MB to 500 MB
B. The application performs mainly read-modify-write-read operations
C. The read cache hit ratio is above 50%
D. The read I/O access pattern is largely random
Answer: D
2. A customer has two 50 GB MirrorView/S mirrored LUNs between two CX3-40s without a Write Intent Log. LUN1 is on SP A and LUN2 is on SP B. The two CX3-40s are connected via dedicated Fibre Channel links.
During the nightly maintenance window, the connection between SP A on the local array and SP A on the remote array is lost for 2 minutes. SP B is unaffected. When the customer logs in the next morning, they notice that LUN1 has a status of "attention" and is still fractured.
What caused this behavior?
A. Auto recovery is not possible on the CLARiiON
B. Missing Write Intent Log
C. Recovery policy is set to Manual
D. SP A set the affected front-end FC port administratively down
Answer: C
3. A customer has set up a disaster recovery site 50 miles (81 km) away from their production site. The customer is using MirrorView/S over IP with the Write Intent Log enabled. In addition, they have a dedicated 45 Mb/s line with a latency of 2 ms. During the testing of the automated solution for disaster recovery, an administrator accidentally disables the Write Intent Log. What is the likely outcome of this error if a secondary image becomes fractured?
A. The fracture log will continue to maintain a log of changed blocks.
B. The fracture log will continue to persistently maintain a log of changed blocks.
C. The Write Intent Log will flush all records of changes.
D. The Write Intent Log will hold change records up to the point where it was disabled.
Answer: A
4. Click the Exhibit button.
Based on the exhibit, what happened between 05:21 A.M. and 06:56 A.M.?
A. CLARiiON back-end port was disconnected
B. CLARiiON front-end port was disconnected
C. MirrorView connection failed
D. SAN Copy connection failed
Answer: C
5. A new CLARiiON arrives at a customer’s site and an EMC Customer Engineer performs the physical installation. The storage administrator is under a lot of pressure to have the array online and in production by the end of the week. The storage administrator selects several Windows and Solaris servers for the initial production rollout. The storage requirements have been agreed upon and the storage administrator creates 30 LUNs of various sizes based upon EMC best practices.
The administrator works with the server team to install HBAs, update settings, install EMC software, and then perform the necessary cabling and zoning requirements. After the hosts successfully register with the CLARiiON array, the Windows and Solaris administrators state each server has 30 LUNs allocated.
What does the storage administrator need to accomplish to ensure each server has access to the appropriate LUNs?
A. Create the appropriate storage groups
B. Disable Access Logix
C. Enable Access Logix
D. Fix the incorrect zones
Answer: C
6. You are a storage administrator who has been tasked with sizing a database LUN for an Exchange 2007 mailbox server. You have been provided with the following information regarding basic capacity requirements:
450 users
200 MB mailbox size
2.5 MB mail sentday
Deleted items retained for 14 days
Deleted mailboxes retained for 30 days
You have also been provided with additional information regarding usage and maintenance processes:
Online maintenance takes 3 days to complete
Approximately five mailboxes are deleted during an average month
Content indexing will not be performed
Offline maintenance will be performed on a separate LUN
Which approximate LUN size will satisfy the listed requirements and still allow for 20% yearly growth?
A. 145 GB
B. 175 GB
C. 355 GB
D. 455 GB
Answer: B
7. Click the Exhibit button.
A customer is complaining that SAN Copy sessions from CLARiiON-A to CLARiiON-B take substantially longer than from those to CLARiiON-C. All hosts have 4 Gb/s HBAs. All Cisco equipment is base hardware configurations.
Which component is causing the issue?
A. 9020s
B. 9216
C. HBAs
D. Hosts
Answer: B
8. A customer runs its critical Oracle environment through a Fibre Channel connection to a CX3-40c. In order to leverage the existing iSCSI connections, management decides to allocate a small amount of storage to support several Windows file servers. The customer needs to make certain that the Oracle SLA is not impacted by the non-critical Windows file servers. Which solution do you recommend?
A. Use Navisphere Quality of Service Manager to set limits on applications connected through iSCSI
B. Change the write aside cache value for Windows LUNs
C. Use Navisphere Service Taskbar to assign a higher SLA to the Oracle environment
D. CX3-40c will automatically assign higher priority to FC connections over iSCSI
Answer: A